AC not cooling

AC not cooling in Casselberry, Florida

If the air conditioner is producing no cool air at all, start with power and airflow: a tripped breaker, a condensate float switch that has shut the system down, or a filter so blocked the coil has frozen. Those three account for most no-cooling calls in Central Florida homes.

Diagnosis

What is most likely wrong

Likely causes, ordered by how often they turn out to be the answer
#CauseHow commonWhat it looks like
1Tripped breaker or pulled disconnectVery commonThermostat calls, nothing outside runs at all.
2Condensate float switch trippedVery commonIndoor unit dead, outdoor unit dead, no fault light. A full drain pan or a blocked line is behind it.
3Blocked filter, frozen evaporator coilVery commonWeak or no airflow at the vents, ice on the copper line at the air handler.
4Failed run capacitorCommonCondenser hums but the fan does not spin, or it spins if you nudge it (do not).
5Failed contactorCommonIndoor blower runs, outdoor unit never starts, sometimes a buzz at the contactor.
6Refrigerant leakLess commonGradual loss of cooling over weeks, then none. Ice or oil residue near a fitting.
7Failed compressorLess commonCondenser fan runs, the compressor does not, or it trips its overload after a few seconds.
Before you call

What you can safely check yourself

  • Thermostat set to cool, fan on auto, and set below the current room temperature. Batteries if it takes them.
  • Both breakers — there is usually one for the air handler and one for the condenser. Reset a tripped breaker once. If it trips again, stop.
  • The outdoor disconnect box beside the condenser: the pull-out should be fully seated.
  • The filter. If it is grey and matted, replace it and leave the system off for a few hours if there is any ice.
  • The condensate drain: a full secondary pan or a wet ceiling stain means the float switch has done its job.
  • The condenser coil: grass clippings, mulch and pool-cage debris pack into it. Rinse from the inside out with the power off at the disconnect.
Where the licensed line is

Refrigerant, capacitors and the inside of an electrical panel are not homeowner jobs.

A run capacitor holds a lethal voltage after the disconnect is pulled. Refrigerant handling requires EPA Section 608 certification. And in Florida the work itself is regulated: an air conditioning contractor licensed under Chapter 489 may replace, disconnect and reconnect the power wiring at the dedicated disconnect, and repair or replace disconnects, breakers and fuses on dedicated HVAC circuits — s. 489.105(3). That scope exists precisely because this work is not general-purpose electrical work.

Verify any Florida licence, including ours, at the DBPR licensee search.

In Casselberry

Why this happens in this housing stock

Two of the top three causes above are humidity-driven, and that is not a coincidence in a city with more than thirty lakes and ponds inside seven square miles. Sustained dewpoints in the seventies mean the evaporator coil is condensing water for most of nine months, and everything downstream of that — drain line, pan, float switch — is a wear point rather than an afterthought. Drain line clearing at a researched $80–$250 is the routine Florida call.

The other local factor is age. The median Casselberry home was built in 1977 and 57.1% of the city was built 1970–89. In that stock a single undersized central return is common, which makes a dirty filter far more consequential: the system is already near its airflow limit before the filter starts restricting it. How often to change it here.

Seminole County Property Appraiser CAMA extract (Parcels.csv, dated 2026-09-05). Improved residential parcels — single-family, townhome and condominium — in city tax district C1, City of Casselberry. n = 8,563.

Cost

What the fix typically costs

Researched repair ranges for this symptom
JobResearched rangeWhat drives it
Diagnostic visit$75–$150Usually credited to the repair. After hours costs more.
Drain line clearing$80–$250The routine local call.
Capacitor replacement$150–$400Most common single part failure on a Florida condenser.
Contactor or relay$100–$450A wear item.
Refrigerant leak repair$200–$1,500+Finding the leak is most of the cost.
Compressor replacement$1,000–$3,000+The point where replacement gets costed properly.
Read this before you use any number on this page

These are researched market ranges, not our prices and not a quote.

The dollar figures below come from published third-party cost guides — named and linked at the foot of the page — and from the City of Casselberry’s own published permit fee. They are here so you can tell whether a quote you have been handed is in the ordinary range for this work. They are not an offer, and no two houses in Casselberry cost the same to do.

Not getting anywhere?

Tell us the symptom, the build year of the house and roughly how old the equipment is. That usually narrows it to two candidates before anyone drives out.